Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture

  • Choi, Sungwook; 
  • Lee, Tong Joo; 
  • Kim, Shinil; 
  • Cho, Changhee; 
  • Shim, Seungjae; 
  • 외 1명
Citations

WEB OF SCIENCE

7
Citations

SCOPUS

9

초록

TTo evaluate the clinical and radiological results of the treatment of complex tibial shaft fracture (AO/OTA type 42-C) with minimally invasive plate osteosynthesis(MIPO). Twenty patients diagnosed with complex tibial shaft fracture without extension to the articular surface and treated with MIPO, including 9 cases of AO/OTA type 42-C2 and 11 cases of AO/OTA type 42-C3, 6 of which were open fractures. External fixation was used for open fractures until the soft tissue damage had healed; then, 2nd stage operation with MIPO was performed to stabilize the fracture. Each patient was followed up for a minimum of 12 months. The mean time to union was 20.1 weeks. Delayed union was observed in 4 cases. Angular deformity, length shortening and non-union were not observed. Severely comminuted and open fractures of the tibial shaft may benefit from temporary external fixation prior to performing MIPO.

키워드

Complex tibial shaft fracture; Minimally Invasive Plate Osteosynthesis; Temporary external fixation; Locking compression plate; DISTAL TIBIA; FOLLOW-UP; CLASSIFICATION; MANAGEMENT; SCREWS; NAIL
제목
Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture
저자
Choi, Sungwook; Lee, Tong Joo; Kim, Shinil; Cho, Changhee; Shim, Seungjae; Kang, Hyunseong
발행일
2019-06
유형
Article
저널명
Acta Orthopaedica Belgica
권
85
호
2
페이지
224 ~ 233