Effect of opening area on the suppression of self-ignition of high-pressure hydrogen gas leaking in the air by an extension tube

Citations

WEB OF SCIENCE

38
Citations

SCOPUS

45

초록

The most influential factor for self-ignition of high-pressure hydrogen is known to be the strength of the shock. Thus, the self-ignition can be suppressed by weakening the shock strength, which is possible by reducing the area where the hydrogen is ejected in this study. To confirm the possibility of this method, experiments were done by controlling the burst pressure of up to 302 bar and the ratio of the opening area. The experimental results showed that the minimum burst pressure of self-ignition is increased exponentially as the opening area is reduced. This confirmed that reducing the opening area under the same burst pressure conditions has an effect on the suppression of self-ignition. However, it was also found that the minimum shock speed that causes self-ignition gradually decreases as the opening area becomes smaller, which results from an increasing in mixing. The CFD simulation results showed that the volume of the flammable region in the tube was increased and the hydrogen-air mixing efficiency also increased when the opening area became smaller. The results suggest that reduction of the opening area can suppress a self-ignition by weakening the shock strength, but it should be noted that an increase in mixing effect also occurs. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

키워드

High-pressure hydrogenSelf-ignitionOpening area ratioShock strengthMixing effectSHOCK-WAVE PROPAGATIONFLAME PROPAGATIONSUDDEN RELEASEOBSTACLESDISCHARGEADDITIONSGEOMETRYDISKJET
제목
Effect of opening area on the suppression of self-ignition of high-pressure hydrogen gas leaking in the air by an extension tube
저자
Cha, Seung-WonRoh, Tae-SeongLee, Hyoung Jin
DOI
10.1016/j.ijhydene.2020.11.132
발행일
2021-01-27
유형
Article
저널명
International Journal of Hydrogen Energy
46
7
페이지
5904 ~ 5915