상세 보기
초록
Recently LED Lighing has received a lot of attention from various industry fields because of its high efficiency, long lifetime, environment-friendly characteristics. This paper presents a LED driver circuit based on single-stage flyback converter with power factor correction. Because of discontinues conduction mode, the converter is able to correct power factor without additional circuit. The proposed flyback converter is composed by a LC filter for reducing 120[Hz] ripples and removing electrolytic capacitor. PI controller is used to maintain constant current of LED lighting. To verify the performance, the proposed circuit is confirmed by simulation.
- 제목
- LED 조명용 전해커패시터와 120[Hz] 리플 제거를 위한 PFC 단일단 불연속 전도모드 플라이백 컨버터
- 제목 (타언어)
- Single-Stage PFC DCM Flyback Converter without the Electrolytic Capacitor and 120[Hz] Ripple for LED Lighting
- 저자
- KIM YOUNG SEOK
- 학회명
- 대한전기학회 추계학술대회
- 개최지
- 한밭대학교
- 학회 개최일
- 2012-11-02 ~ 2012-11-03