The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from –8.9% to 9% and –10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from –14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from –15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.
키워드
- 제목
- 척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가
- 제목 (타언어)
- Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery
- 저자
- 강동진; 오건; 신영주; 강진규; 정재용; 이보람
- 발행일
- 2023-12
- 유형
- Y
- 저널명
- 방사선기술과학
- 권
- 46
- 호
- 6
- 페이지
- 527 ~ 533