DESIGN AND VERIFICATION OF COOLING FANS FOR ENGINE ROOMS OF MOBILE HYDRAULICS VEHICLES

  • Kim, J. -H.
  • Lee, G. P.
  • Lim, C. H.
  • Lee, S.
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

To provide an engine room of mobile hydraulic vehicle with an effective cooling for the combination set of a radiator, a charge air cooler, and an oil cooler, a 500mm-diameter, axial fan is designed to have a 8,800 m(3)/hr at a resistance of 20mm Aq static pressure with a sound power level less than 86 Lw(A). The design parameters of sweep angle amplitude, wavelength of sweep angle change, airfoil type, and stagger angle are examined in terms of fan performance and its sound power generation. The surface curvatures generated by the sinusoidal sweep angle variation in the radial direction are proved to result in quite different flow patterns, thereby different types of specific sound power characteristics at the same flowrate. The acoustic noise sources are examined and discussed by using an acoustic imaging technique.

키워드

Forklift Engine NoiseCooling FanSound PowerNature-inspired DesignEagle-wing Airfoil
제목
DESIGN AND VERIFICATION OF COOLING FANS FOR ENGINE ROOMS OF MOBILE HYDRAULICS VEHICLES
저자
Kim, J. -H.Lee, G. P.Lim, C. H.Lee, S.
발행일
2019
유형
Proceedings Paper
저널명
PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3A