A comparative pilot-scale evaluation of gas-sparged and granular activated carbon-fluidized anaerobic membrane bioreactors for domestic wastewater treatment
- Evans, Patrick J.;
- Parameswaran, Prathap;
- Lim, Kahao;
- Bae, Jaeho;
- Shin, Chungheon;
- 외 2명
WEB OF SCIENCE
53SCOPUS
62초록
Two significantly different pilot-scale AnMBRs were used to treat screened domestic wastewater for over one year. Both systems similarly reduced BOD5, and COD by 86-90% within a 13-32 degrees C temperature range and at comparable COD loading rates of 1.3-1.4 kg-COD m(-3) d(-1) and membrane fluxes of 7.6-7.9 L m(-2) h(-1) (LMH). However, the GAC-fluidized AnMBR achieved these results at a 65% shorter hydraulic retention time than the gas-sparged AnMBR. The gas-sparged AnMBR was able to operate at a similar operating permeability with greater reactor concentrations of suspended solids and colloidal organics than the GAC-fluidized AnMBR. Also, the membranes were damaged more in the GAC-fluidized system. To better capture the relative advantages of each system a hybrid AnMBR comprised of a GAC-fluidized bioreactor connected to a separate gas-sparged ultrafiltration membrane system is proposed. This will likely be more effective, efficient, robust, resilient, and cost-effective.
키워드
- 제목
- A comparative pilot-scale evaluation of gas-sparged and granular activated carbon-fluidized anaerobic membrane bioreactors for domestic wastewater treatment
- 저자
- Evans, Patrick J.; Parameswaran, Prathap; Lim, Kahao; Bae, Jaeho; Shin, Chungheon; Ho, Jaeho; McCarty, Perry L.
- 발행일
- 2019-09
- 유형
- Article
- 권
- 288