Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis

  • Cha, Yonghan
  • Chung, Jun Young
  • Jung, Chang-Ho
  • Kim, Jin-Woo
  • Lee, Jeyoon
  • ... Yoo, Jun-Il
  • 외 2명
Citations

WEB OF SCIENCE

12
Citations

SCOPUS

14

초록

BackgroundFemoral neck fractures are a common injury in older adults and their management presents a significant challenge for orthopedic surgeons. The Femoral Neck System (FNS) was recently introduced for the fixation of femur neck fractures. Although neck shortening was reduced with the FNS, the complication rates were not reduced. Thus, improvements to enhance fixation stability should be made for the FNS. We hypothesized that (1) the pre-sliding technique and (2) the use of longer anti-rotation screw would increase fracture stability. This study aimed to determine the change in fracture stability using the pre-sliding technique and long anti-rotation screw in the FNS for fixation of Pauwels type III femoral neck fractures.MethodsFinite element models of Pauwels type III femoral neck fracture fixed with pre-sliding FNS and 5-mm longer anti-rotation screw were established. The models were subjected to normal walking load. The material properties of the elements belonging to the bone were mapped by assigning the formulation with the computed tomography Hounsfield unit.ResultsPauwels type III femoral neck fractures fixed with pre-slided FNS showed better fracture stability, decreasing fracture gap and sliding by 14% and 12%, respectively, under normal walking load. No element of cortical bone in any of the models had an absolute value of principal strain that exceeded 1%. The peak von Mises stress (VMS) of the implants ranged from 260 to 289 MPa, and the highest peak VMS value was 50% lower than the yield strength of the titanium alloy (800 MPa). The longer anti-rotation screw did not affect fracture stability.ConclusionsThe pre-sliding technique using the FNS showed higher fracture stability than the standard fixation technique for a Pauwels type III femoral neck fracture. The longer anti-rotation screw did not contribute significantly to fixation stability. As this finite element analysis considered the inhomogeneous mechanical property of the bone, it offered equivalent mechanical conditions to investigate the components of interest.

키워드

Anti-rotation screwFemoral Neck SystemPauwels type III neck fracturePre-sliding techniqueINTERNAL-FIXATIONHIP-JOINTMANAGEMENTSCREW
제목
Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis
저자
Cha, YonghanChung, Jun YoungJung, Chang-HoKim, Jin-WooLee, JeyoonYoo, Jun-IlKim, Jung-TaekJeon, Yongho
DOI
10.1186/s12891-023-06631-3
발행일
2023-06-21
유형
Article
저널명
BMC Musculoskeletal Disorders
24
1