In this work, the heating performances of electroless Ni-P plated carbon fibers (MCF) at different heat treatment temperatures (300, 400, 500, and 700 degrees C) were investigated using an infrared thermal imaging camera. From the experimental results, we found that the MCF was a mixture of microcrystalline and amorphous phases, as indicated by XRD. In addition to the stable Ni, Ni3P, and NiO phases, the metastable NisP phase was also observed although the amount was small. A higher heat treatment temperature of 400 degrees C resulted in the growth of Ni and Ni3P phases indicated by the stronger peak intensity. However, the specific resistance increased as the heat treatment temperature increased above 400 degrees C. Accordingly, the performance of heat-treated MCF as electrical heating elements was strongly dependent on the surface structure of the MCF as well as the heat treatment temperature. The MCF exhibited a low electrical heating temperature (31.0 degrees C), while MCF-H400 exhibited an excellent electrical heating temperature (102.0 degrees C) along with rapid temperature response and high heat output to maintain a maximum temperature at a given applied voltage.
키워드
- 제목
- Influence of heat treatment temperature on structure and exothermic properties of electroless Ni-P plating carbon fiber heating elements
- 저자
- Choi, Bo-kyung; Choi, Woong-Ki; Rhee, Kyong Yop; Park, Soo-Jin; Seo, Min-Kang
- 발행일
- 2019-06-15
- 유형
- Article
- 권
- 167
- 페이지
- 676 ~ 682