Analysis of Transient Electric Fields Caused by the Operation of Impulse Voltage Generator

임펄스 전압 발생기의 동작에 따른 과도전계의 분석
  • BOK HEE LEE

초록

The transient electric fields, which originate from the operations of a high voltage experimental apparatus and Marx generator, were measured and analyzed by means of the Fast Fourier Transform(FFT) method. The plannar-type electric field measuring system has been developed. The signal transmission system consists of optical fiber links to prevent the effect of electromagnetic disturbances. The electric field measuring system showed a very good step response characteristic and its frequency bandwith was the range from 12Hz to 12 MHz with an amplification factor of 5.

제목
Analysis of Transient Electric Fields Caused by the Operation of Impulse Voltage Generator
제목 (타언어)
임펄스 전압 발생기의 동작에 따른 과도전계의 분석
저자
BOK HEE LEE
학회명
Proc. of the 5th ICPADM