상세 보기
Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method
- Lee, Jin-sung;
- Kim, Kyung-su;
- Kim, Yooil
WEB OF SCIENCE
4SCOPUS
4초록
Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale N096 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale N096 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method. Copyright (C) 2018 Production and hosting by Elsevier B.V. on behalf of Society of Naval Architects of Korea.
키워드
- 제목
- Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method
- 저자
- Lee, Jin-sung; Kim, Kyung-su; Kim, Yooil
- 발행일
- 2018-07
- 유형
- Article
- 권
- 10
- 호
- 4
- 페이지
- 458 ~ 467