Evaluation of distance and angular dependence of polycrystalline semiconductor dosimeters for Ir-192 brachytherapy source using experimental measurements and Monte Carlo simulations

  • Han, M. J.
  • Kang, S. W.
  • Eom, K. Y.
  • Kim, I. A.
  • Kim, J. S.
  • ... Lee, B.
  • 외 2명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Background: This study evaluates the distance and angular dependence of polycrystalline semiconductor-based dosimeters (PSDs) using lead (II) iodide (PbI 2) (PbI2 PSD) and lead (II) oxide (PbO) (PbO PSD) for Ir-192 brachytherapy source. Experimental measurements were compared with Monte Carlo (MC) simulations to verify the dosimeters' performance and accuracy. Materials and Methods: PSDs were fabricated using PbI2 and PbO as photoconductive materials, with a thin-film deposition process ensuring uniformity. Distance dependence was assessed by measuring dosimeter responses at source-to-surface distances ranging from 1 cm to 8 cm at 0.25 cm intervals, while angular dependence was evaluated at angles from 0 degrees to 60 degrees in 15 degrees increments. MC simulations using the Geant4 Application for Tomographic Emission (GATE) v9.1 were conducted under identical conditions to validate the experimental measurements. Results: The experimental and simulated data demonstrated a strong agreement with the inverse-square law, with determination coefficient (R-2) exceeding 0.98 for PbI2 and PbO PSDs. The distance at which the signal intensity dropped by 50% (D50) for measurements and simulations was 1.493 cm and 1.487 cm for PbI2 PSD, respectively, and 1.488 cm and 1.481 cm for PbO PSD. Angular dependence analysis showed a decrease in response with increasing angle, with PbO PSD exhibiting slightly larger discrepancies (maximum difference of 5.48%) compared to PbI2 PSD (maximum difference of 4.56%) between measurements and simulations. Conclusion: PbI2 and PbO PSDs demonstrated predictable distance and angular dependence, closely aligning with MC simulations. However, angular correction factors may be necessary to improve dosimetric accuracy in clinical applications.

키워드

Dosimeterssemiconductorsbrachytherapyiridium-192 radioisotopeMonte Carlo simulationquality assurance
제목
Evaluation of distance and angular dependence of polycrystalline semiconductor dosimeters for Ir-192 brachytherapy source using experimental measurements and Monte Carlo simulations
저자
Han, M. J.Kang, S. W.Eom, K. Y.Kim, I. A.Kim, J. S.Lee, B.Cho, W.Chung, J. B.
DOI
10.61186/ijrr.24.2.3
발행일
2026-04
유형
Article
저널명
International Journal of Radiation Research
24
2
페이지
317 ~ 322