상세 보기
초록
This study develops a thermodynamic analysis method to determine thermal efficiency and provide information regarding capacity design specification for each system component. A chain-block structure analysis method is introduced for heat recovery boilers with water-spray (HR-B/WS), where water is sprayed onto the inlet air stream and/or reaction zone. We subsequently validated the proposed analysis method and investigated the boiler system practically. HR-B/WSs are expected to achieve up to 95% efficiency with reduced NOX emission. Additional water spray onto the combustion chamber may be a useful mechanism to reduce NOX emission while retaining high efficiency when insufficient water is supplied to the heat exchanger.
키워드
Thermodynamic analysis; Chain-block structure method; Heat recovery boiler; Water spray; High efficiency; Low NOX emission; EXHAUST-GAS RECIRCULATION; FLUE-GAS; WASTE-HEAT; COMBUSTION CHARACTERISTICS; RELATIVE-HUMIDITY; FIRED BOILER; EFFICIENCY; SYSTEM; AIR
- 제목
- Heat recovery boilers with water spray. Part I: Thermodynamic analysis validation and boiler practicality
- 저자
- Lee, Chang-Eon; Kim, Do-Hyun
- 발행일
- 2020-08-01
- 유형
- Article
- 저널명
- THERMAL SCIENCE AND ENGINEERING PROGRESS
- 권
- 18