상세 보기
초록
The water level of the dam reservoir is an important data in the operation of the dam. reservoir storage can be calculated by using water levels or prepared for disasters such as drought and floods. However, the water level is measured near the dam, making it difficult to represent a reservoir with a large area, and there is a high possibility that the water surface will be distorted due to discharge. Furthermore, the results of the survey showed that the water level of the reservoir is irregular rather than constant, and the water level of the reservoir is repeatedly falling and rising by section. In order to calculate such a complex and irregular representative water level, the water level observation density of the reservoir must be increased. In this study, we tried to derive the optimum water level observation density for Hwacheon Dam. A reasonable water level measurement density was derived by investigating the water level elevation of the reservoir and statistically analyzing it. The observation density may vary depending on the size of the reservoir, so the same analysis was conducted on the Goesan Dam and Boseonggang Dam. According to the results, four Hwacheon dams, three Goesan dams, and seven Boseong River dams are needed for observation density. © 2022 Korea Water Resources Association. All rights reserved.
키워드
- 제목
- Empirical recommendation for planning the observation density of water level in a reservoir (Case study on Hwacheon Dam in Korea)
- 저자
- Hwang-Bo, Jong Gu; Hong, Jun Hyuk
- 발행일
- 2022
- 유형
- Article
- 저널명
- 한국수자원학회 논문집
- 권
- 55
- 호
- 10
- 페이지
- 835 ~ 841