상세 보기
초록
Continous flow peritoneal dialysis(CFPD)-based extracircuit model provided acceptable fluid, electrolytes, and uremic control with keeping cells in the bioartificial renal epithelial cell system device viable and functional forup to 7days. The present 24 hour-miniature CFPD can be applied to peritoneal-based wearable bioartificial kidney in the future.
- 제목
- Bioartificial kidney 장착을 위한 지속유량복막투석 동물모델
- 제목 (타언어)
- Animal model of continous flow peritoneal dialysis for Bioartificial kidney
- 저자
- KIM MOONJAE
- 학회명
- 제29차 대한신장학회 춘계학술대회
- 개최지
- 서울
- 학회 개최일
- 2009-05-15 ~ 2009-05-17