Changes of Resection Goal After Using 3-Dimensional Printing Brain Tumor Model for Presurgical Planning
- Kim, Kyung-Min;
- Byun, Yoon Hwan;
- Kang, Ho;
- Kim, Min-Sung;
- Kim, Jin-Wook;
- 외 3명
WEB OF SCIENCE
2SCOPUS
2초록
BACKGROUND: Conventional 2-Dimensional magnetic resonance imaging-based neuronavigation systems can improve the maximal safe resection in brain tumor surgery but can be unintuitive. A 3-Dimensional (3D)-printed brain tumor model allows for a more intuitive and stereoscopic understanding of brain tumors and adjacent neurovascular structures. This study aimed to identify the clinical efficacy of a 3D-printed brain tumor model in presurgical planning by focusing on differences in the extent of resection (EOR). METHODS: Thirty two neurosurgeons (14 faculty members, 11 fellows, 7 residents) randomly selected the two 3D-printed brain tumor models from the 10 manufactured models and performed presurgical planning following a standardized questionnaire. To compare the 2-Dimensional magnetic resonance imaging-based planning results with the 3D-printed model-based planning results, we analyzed the changing patterns and characteristics of the EOR. RESULTS: Of 64 randomly generated cases, the resection goal changed in 12 cases (18.8%). When the tumor was located intra-axially, the surgical posture required a prone position, and when the neurosurgeon was dexterous in surgery, there was a higher rate of EOR changes. 3D-printed models 2, 4, and 10, which all represented tumors in the posterior of the brain, had high rates of changing EOR. CONCLUSIONS: A 3D-printed brain tumor model could be utilized in presurgical planning to effectively determine the EOR.
키워드
- 제목
- Changes of Resection Goal After Using 3-Dimensional Printing Brain Tumor Model for Presurgical Planning
- 저자
- Kim, Kyung-Min; Byun, Yoon Hwan; Kang, Ho; Kim, Min-Sung; Kim, Jin-Wook; Kim, Yong Hwy; Park, Chul-Kee; Dho, Yun-Sik
- 발행일
- 2023-09
- 유형
- Article
- 권
- 177
- 페이지
- E153 ~ E160