상세 보기
초록
As outdoor air quality is deteriorated by fine dust, mechanical ventilation becomes essential especially for classrooms that have a high occupancy rate. However, mechanical ventilation in classrooms may not operate for a reason that noise during classes disturbs student's concentration. The purpose of this study is to propose a control method that can keep the noise level and CO2 concentration within an acceptable range. Experimentation of the proposed control method has achieved at a university classroom of 230 m3 volume, and simulation analysis is achieved to compare the control method with a reference case. Results show that the proposed method can keep the CO2 level under 2000 ppm for classes of a duration of 75 min even when the lowest ventilation rates are adopted during lectures.
키워드
- 제목
- 풍량 제어를 통한 수업 중 환기장치 운전 소음 저감 방안
- 제목 (타언어)
- Operating Method of Classroom Ventilators for Mitigating Operating Noise
- 저자
- 김선인; 박승훈; 조재훈; 김의종
- 발행일
- 2020-06
- 유형
- Y
- 저널명
- 한국건축친환경설비학회 논문집
- 권
- 14
- 호
- 3
- 페이지
- 260 ~ 270