Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video)

  • Takenaka, Mamoru
  • Minaga, Kosuke
  • Kamata, Ken
  • Yamao, Kentaro
  • Yoshikawa, Tomoe
  • ... Jeong, Seok
  • 외 13명
Citations

WEB OF SCIENCE

22
Citations

SCOPUS

27

초록

Background Balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (BE-ERCP) has been reported to be effective for patients with surgically altered gastrointestinal anatomy. However, selective biliary cannulation remains difficult in BE-ERCP. We examined the usefulness of a modified double-guidewire technique using an uneven double lumen cannula (the uneven method) for BE-ERCP in patients with surgically altered gastrointestinal anatomy. Methods To clarify the usefulness of the uneven method for selective biliary cannulation in BE-ERCP in comparison to the pancreatic guidewire (PGW) method, 40 patients with surgically altered gastrointestinal anatomy who underwent BE-ERCP with successful placement of a guidewire in the pancreatic duct were evaluated. The uneven method was used in 18 cases (uneven group) and the PGW method was used in the remaining 22 cases (PGW group). Results The technical success rate of biliary cannulation was higher in the uneven group than in the PGW group (83.3 vs. 59.0%; P = 0.165). In addition, the time to biliary cannulation were significantly shorter in the uneven group than in the PGW group (6 vs. 18 min; P = 0.004; respectively). In the PGW group, post-ERCP pancreatitis (PEP) occurred in 3 of 22 cases (13.6%). No adverse events, including PEP, occurred in the uneven group. Conclusions The uneven method may be a useful option of selective biliary cannulation in BE-ERCP for the patients with surgically altered gastrointestinal anatomy.

키워드

ERCPBalloon enteroscopy-assisted ERCPPatients with surgically altered gastrointestinal anatomyThe uneven methodSELECTIVE BILIARY CANNULATIONENTEROSCOPY-ASSISTED ERCPBILE-DUCT CANNULATIONGASTRECTOMYPLACEMENTSTONES
제목
Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video)
저자
Takenaka, MamoruMinaga, KosukeKamata, KenYamao, KentaroYoshikawa, TomoeIshikawa, ReiOkamoto, AyanaYamazaki, TomohiroNakai, AtsushiOmoto, ShunsukeKomeda, YoriakiSakurai, ToshiharuWatanabe, TomohiroNishida, NaoshiChiba, YasutakaKwon, Chang-IlJeong, SeokLee, Tae HoonKudo, Masatoshi
DOI
10.1007/s00464-019-07228-5
발행일
2020-03
유형
Article
저널명
Surgical Endoscopy
34
3
페이지