Structural Integrity Assessments of an IMO Type C LCO2 Cargo Tank

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

2

초록

With the rise of carbon capture and storage, liquefied carbon dioxide (LCO2) has emerged as a promising medium for large-scale marine transport. This study evaluates the structural integrity of an IMO Type C cargo tank for a medium-range LCO2 carrier under four conditions: ultimate limit state, accidental limit state, hydrostatic pressure test, and fatigue limit state, based on IGC Code and classification rules. Seventeen load cases were analyzed using finite element methods with multi-step loading to ensure stability. The highest stress occurred at the pump dome-shell junction due to geometric discontinuities, but all stress and buckling criteria were satisfied. The fatigue damage from wave-induced loads was negligible, with low-cycle fatigue from loading/unloading operations governing the fatigue life, which exceeded 31,000 years. The findings confirm the tank's structural robustness and its suitability for safe, efficient medium-pressure LCO2 transport.

키워드

LCO2 tankULSALSFLSHPTdesign vapor pressure
제목
Structural Integrity Assessments of an IMO Type C LCO2 Cargo Tank
저자
Kim, JoonPark, Kyu-SikCha, InhwanChoung, Joonmo
DOI
10.3390/jmse13081479
발행일
2025-07
유형
Article
저널명
JOURNAL OF MARINE SCIENCE AND ENGINEERING
13
8