Treatment of waste solution of waste refrigerant decomposition process using atmospheric pressure plasma

Citations

SCOPUS

2

초록

Our group reported the thermal decomposition of R-22 (CHClF 2 ) refrigerants by nitrogen thermal plasma in previous studies. However, it was proposed that the wastewater generated from the end part of the process contains high concentration of fluoride ion which is a component of R-22. The additional post-treatment process to neutralize the F - ions in the wastewater was investigated in this study. The wastewater generated through the decomposition of R-22 with the same procedure in the previous work was treated using the neutralizer, Ca(OH) 2 , and the atmospheric pressure plasma jet (APPJ) independently as a post-treatment process. Wastewater samples were collected directly after the treatment for ion-chromatography analysis to trace the change of the concentration of F - ion in the wastewater. The fluoride concentration in the wastewater showed the highest value when the single water was used as a neutralizer, and the concentration of fluoride in the wastewater was dramatically reduced when the post-treatments were performed. © 2018, Korean Society of Industrial Engineering Chemistry. All rights reserved.

키워드

CHClF <sub>2</sub>HCFC-22N <sub>2</sub> thermal plasmaWater waste treatment
제목
Treatment of waste solution of waste refrigerant decomposition process using atmospheric pressure plasma
저자
Ko, Eun HaYoo, HyeonseokJung, Yong-AnPark, Dong-WhaKim, Dong-WookChoi, Jinsub
DOI
10.14478/ace.2018.1026
발행일
2018
유형
Article
저널명
공업화학
29
4
페이지
479 ~ 483