In order to increase the energy independence of smart farms, this study built a demonstration site and analysed related data by integrating an air-type PVT (photovoltaic-thermal) system that can be installed on the wall of a smart farm with an ERV (energy recovery ventilator) for CO2 control used in smart farms. Measured during the summer season from July to October, the results mainly analysed the performance of PVT modules, and found that the electrical efficiency was 9.4% to 11.0% and the thermal efficiency was 35.1% to 40.0%, with a wider distribution due to changes in external conditions compared to the outdoor performance test, but the overall thermal and electrical performance was similar.