상세 보기
초록
This work presents a hysteresis model of ER fluid with respect to the applied electric field. After confirming congruent and minor properties of ER fluid, Preisach model which contains temperature effect is established to identify the field-dependent hysteresis. In addition, tracking control performance is evaulated by implementing the feedforward compensator.
- 제목
- Preisach Model of ER Fluids Considering Temperature Variations
- 저자
- CHOISEUNG BOK
- 학회명
- 9th International Conference on ER Fluids and MR Suspensions